Care building · Domestic hot water

Domestic hot water in care building: what the SRI measures

Domestic hot water covers the boiler or storage tank: is water heated on a fixed schedule or based on use, can the system use cheap electricity or solar heat, and is the circulation pump controlled smartly.

In short

  1. 1Control of hot water generation, storage and circulation.
  2. 2Weight of this domain for this building type: heavy.
  3. 3If everything in this domain is at level 0, the domain contributes nothing. At the highest level for all services, the indicative total score for this building type rises by about 8 percentage points (from 31 to 39 percent, with all other domains at level 1).

Weight of this domain for this building type

heavy

Which services count

ServiceLowest levelHighest levelAdvice
Control of DHW storage charging (with direct electric heating or integrated electric heat pump)
DHW-1a · A · 3 levels
Automatic control on / offAutomatic on/off control, scheduled charging enable and demand-based supply temperature control or multi-sensor storage managementhighest level
Control of DHW storage charging
DHW-1b · A · 3 levels
NoneAutomatic charging control based on local availability of renewables or information from electricity grid (DR, DSM)highest level
Control of DHW storage charging (with solar collector and supplementary heat generation)
DHW-1d · 4 levels
Manual selected control of solar energy or heat generationAutomatic control of solar storage charge (Prio. 1) and supplementary storage charge, demand-oriented supply and return temperature control and multi-sensor storage management
Sequencing in case of different DHW generators
DHW-2b · 5 levels
Priorities only based on running timeControl according to dynamic priority list (based on current AND predicted load, energy efficiency, carbon emissions, capacity of generators AND external signals from grid)
Report information regarding domestic hot water performance
DHW-3 · A · 5 levels
NonePerformance evaluation including forecasting and/or benchmarking; also including predictive management and fault detectionhighest level

Worked example

If everything in this domain is at level 0, the domain contributes nothing. At the highest level for all services, the indicative total score for this building type rises by about 8 percentage points (from 31 to 39 percent, with all other domains at level 1).

What this means for you

Owner
When replacing or renovating in this domain, include the controls right away. It weighs heavily for this building type.
Tenant
Control of hot water generation, storage and circulation.
Advisor
5 services in this domain, 3 of which in Method A. Advice for this building type: highest level.